力士乐dds伺服驱动器维修说明
力士乐dds伺服驱动器维修说明: Description: Before starting an automatic control loop setting, both travel range limits, i.e., upper and lower, must be defined. 在开始自动控制回路设置之前,即,上部和下部,必须定义。 When starting command P-0-0162, D9 automatic control loop setting the number values are automatically checked for validity. It is checked if the traversing path is large enough and if sensible values have been entered。 当启动指令P-00162时,D9自动控制回路设置数值会自动检查其有效性。 检查遍历路径是否足够大,以及是否输入了合理的值 Possible fault causes:可能的故障原因: • P-0-0167, upper traversing range smaller than P-0-0166, lower traversing range P-0-0167,上部横向范围小于P-0-0166,下部横向范围 • Maximum traversing path (= upper - lower limits) is less than 6 motor rotations and thus too small to start the automatic control loop setting. 最大横向路径(=上限-下限)小于6个电机旋转,因此太小,无法启动自动控制回路设置。 Remedy:解决措施: • clear command error by ending the command 通过结束命令来清除命令错误 • a) input new limits whereby:upper > lower limits a) 输入新的限制,其中:上限>下限 b) redefine limits to define a larger traversing range b) 重新定义极限以定义更大的遍历范围 • restart command with sensible traversing range 具有合理遍历范围的重新启动命令 |